E series Hall Effect leakage current transducer
Leakage current sensor, specifically for detecting micro current, or differential current in two current wires, the range is between 10mA~10A. The primary and secondary sides are highly insulated. The housing complies with the UL94-V0 standard. Disc mounting. Small size, light weight, low power consumption, no insertion loss perforation.
Rated input: 0.01A~2A DC
Output: 75mV, 1V, 4V, 5V optional
Accaracy and linearity: ±1.0%
Temperature drift: 0.05%/℃
Response time:<120mS
Isolation: 3KVRMS/50Hz/1Min
Operating temperature: -25℃~+85℃
Power supply: ±12V,±15V optional
Current consumption: 10mA
WIndow: ø15mm
Overload:20 times of the maximum value of measuring range
CE-IZ04-**E2-1.0
E2 case style(mm)
+: Positive power supply
-: Negative power supply
M: Signal output
G: Ground
Connection diagrams of dual power supply