E series open-loop Hall Effect current transducer
Leakage current sensor, specifically for detecting micro current, or differential current in two current wires, the range is between 10mA~10A. The primary and secondary sides are highly insulated. The housing complies with the UL94-V0 standard. Disc mounting. Small size, light weight, low power consumption, no insertion loss perforation.
Rated input: 500A~4000A DC
Output: 75mV, 1V, 4V, 5V or 0-20mA, 4-20mA optional
Accaracy and linearity: ±1.0%
Temperature drift: 0.025%/℃
Response time:<10µS
Isolation: 3KVRMS/50Hz/1Min
Operating temperature: -25℃~+85℃
Power supply: ±12V,±15V, +12V, +24V optional
Current consumption: 20mA
WIndow: ø67mm
Overload:20 times of the maximum value of measuring range
CE-IZ04-**E11-1.0
E11 case style(mm)
+: Positive power supply
-: Negative power supply
M: Signal output
G: Ground
Connection diagrams of dual power supply
+: Positive power supply
-: NC
M: Signal output
G: Ground
Connection diagrams of power supply