Frequency Transducer

HOME > PRODUCT > Frequency

  • ​ENTRIES:Part Number GuideData SheetFAQ
  • This product is an arbitrary waveform of the frequency signal detection isolation transducer. Adopts the principle of photoelectric isolation, can convert the input frequency signal into linear output of 0 ~ 5V, 0 ~ 20mA, 4 ~ 20mA and other standard signals, the input frequency signal can be a sine wave, square wave and zero-crossing wave, and its amplitude can up to 1000Vpp. This product is two isolation, that is the input and output are isolated from the power supply. Easy installation, can be widely used in communications, electricity, railways, industrial control and other fields.


    Data Sheet

    * Test conditions: auxiliary power supply: +24 V, room temperature: 25°C.

    * Input range: frequency: 0-50Hz~10KHZ, Amplitude: 5-500V;

    * Output: 0-5V, 0-20mA, 1-5V, 4-20mA, 0-10V; 

    * Power supply: DC 12V,15V,24V,AC/DC 85V~265V;         

    * Accuracy: class 0.5;

    * Load capacity: ≥2KΩ (voltage output); ≤300Ω (current output);

    * Temperature drift: <500ppm/°C;

    * Isolation voltage: DC 2500V

    * Response time: ≤200 mS; (Frequency <100Hz, response time <800mS)

    * Rated power consumption: <0.5W

    * Output ripple: <10mV

    * Frequency range: 0Hz~10kHz

    * Surge Immunity: input port four-level 4KV (L-N / 2Ω / integrated wave), 

                                  power supply / output port two-level 2KV (L-N / 40Ω / integrated wave);

    * Impulse immunity:  input / power port ± 2KV, analog I / O port ± 1KV;

    * Input overload capacity: continuous overload: 120%; short-term overload: 2 times of the rated    voltage input value , apply one second;

    * Operating temperature: -10°C~+60°C;

    * Storage conditions: -40°C~+70°C.


    blob.png

    MS2.jpg

    DC auxiliary power supply ( MS2 ) product outline drawing


    MS3.jpg

    220V auxiliary power supply ( MS3 ) product outline drawing


    blob.png

    Installation dimensions

    blob.png

      CE-F01-3*MS2/ CE-F01-8*MS2 connection diagram


    blob.png

      CE-F01-4*MS2/ CE-F01-5*MS2 connection diagram


    blob.png

    CE-F01-*9MS3 connection diagram



    With waveform shaping function, can be arbitrary waveform input measurement;

    Amplitude variation can be as low as 5%;

    Frequency measurement can up to 10KHz;

    Good stability and high precision.


    Related Products

    Copyright© 2019 SHENZHEN SENSOR ELECTRONIC TECHNOLOGY CO., LTD粤ICP备05079934号-9