This product is an arbitrary waveform of the frequency signal detection isolation transducer. Adopts the principle of photoelectric isolation, can convert the input frequency signal into linear output of 0 ~ 5V, 0 ~ 20mA, 4 ~ 20mA and other standard signals, the input frequency signal can be a sine wave, square wave and zero-crossing wave, and its amplitude can up to 1000Vpp. This product is two isolation, that is the input and output are isolated from the power supply. Easy installation, can be widely used in communications, electricity, railways, industrial control and other fields.
* Test conditions: auxiliary power supply: +24 V, room temperature: 25°C.
* Input range: frequency: 0-50Hz~10KHZ, Amplitude: 5-500V;
* Output: 0-5V, 0-20mA, 1-5V, 4-20mA, 0-10V;
* Power supply: DC 12V,15V,24V,AC/DC 85V~265V;
* Accuracy: class 0.5;
* Load capacity: ≥2KΩ (voltage output); ≤300Ω (current output);
* Temperature drift: <500ppm/°C;
* Isolation voltage: DC 2500V
* Response time: ≤200 mS; (Frequency <100Hz, response time <800mS)
* Rated power consumption: <0.5W
* Output ripple: <10mV
* Frequency range: 0Hz~10kHz
* Surge Immunity: input port four-level 4KV (L-N / 2Ω / integrated wave),
power supply / output port two-level 2KV (L-N / 40Ω / integrated wave);
* Impulse immunity: input / power port ± 2KV, analog I / O port ± 1KV;
* Input overload capacity: continuous overload: 120%; short-term overload: 2 times of the rated voltage input value , apply one second;
* Operating temperature: -10°C~+60°C;
* Storage conditions: -40°C~+70°C.
DC auxiliary power supply ( MS2 ) product outline drawing
220V auxiliary power supply ( MS3 ) product outline drawing
Installation dimensions
CE-F01-3*MS2/ CE-F01-8*MS2 connection diagram
CE-F01-4*MS2/ CE-F01-5*MS2 connection diagram
CE-F01-*9MS3 connection diagram
With waveform shaping function, can be arbitrary waveform input measurement;
Amplitude variation can be as low as 5%;
Frequency measurement can up to 10KHz;
Good stability and high precision.