Single phase AC multi-parameter digital transducer
HOME > Multi-parameter > AC Multi-parameter Digital Transducer
This product is a power integrated measurement of single-phase digital isolation transducer. It can measure the full-parameter of the AC circuit. Using high-precision 24-bit dedicated AD chip, the ratio dynamic range can be up to 1000: 1, the measurement parameters are voltage, current, frequency, active power, reactive power, power factor, total accumulative energy and other electrical parameters with high accuracy, good stability and high communication speed, the completely isolated processing technology is with anti-interference ability. Measurement of electrical parameters through the RS-485 digital interface output to achieve long-distance transmission, the product MODBUS protocol is complete compatible with a variety of configuration software or PLC equipment MODBUS (RTU) protocol. It can be applied to power, room monitoring, industrial measurement and other fields.
NO, | Item | Date | Unite | Remarks |
1 | Accuracy | 0.2,0.5 | % | 0.2 for voltage and current value only |
Input range | S3 case:500V*30A; S4 case:500V*500A; ES5 case:500V*700A; N1 case:500V*5A; DS5 case: 500V*200A | The maximum range for each specification | ||
Frequency | Frequency response: 20Hz-1KHz; Frequency measurement: 20-600Hz | |||
2 | Baud rate | 115.2K, 57.6K, 38.4K, 19.2K, 9600(default) 4800, 2400, 1200 | bps | Factory default communication format: 9600, N/8/1, address 1; S5 type up to 19.2K; |
Communication | RS-485(twisted pair line) , RS-232C(treble line, only for N style parts) | RS422 optional | ||
Parity | None, Even, Odd, Space | |||
Max. number of nodes | 64 | Node | Only for RS-485 | |
Bus protection | 400W transient voltage | ESD protection and thermosnap | ||
3 | A/D SPEED | 100 | mS | |
4 | Working temperature | -20℃~+60℃ | ||
5 | Isolation voltage | Input/output: 2500V DC for 1 min Input/power supply:2500V for 1 min Output/power supply:2500V for 1 min |
V | The double isolation part numbers, their output and power supply are grounded together, there is only between the input and output isolation voltage |
6 | Overload | 2 x voltage span 1 sec. 10 for times with interval of 10 sec. 10 x current span for 1 sec. 5 times with an interval of 300 sec (only for hole thru. parts) | The input outside the linear range will result in poor accuracy | |
7 | MTBF | >30000 | hour | |
8 | Auxiliary power supply | +5V/+12V/+24V/+48V/ AC220V | V | 220VAC,DC only for N case parts |
9 | Power consumption | ≤250mW(+12V),≤500mW(+24V) | mW | Power consumption depends on power supply to be used |
10 | Temperature drift | ≤300 | ppm/℃ | (-20℃~+60℃) |
CE-AJ1*-**BS3 Case Type
CE-AJ1*-**BS3 Installation Diagram
CE-AJ1*-**MN1 Case Type( 220 VAC Power Supply is optional)
CE-AJ1*-**MN1 Installation Diagram
CE-AJ1*-**DS5 Case Type
CE-AJ1*-**DS5 Installation Diagram
CE-AJ1*-**ES5 Case Type
CE-AJ1*-**ES5 Installation Diagram
CE-AJ11-**BS3 wiring diagram
(Terminal 7 output is +5 V to provide 5V output (<20mA), figure 6.2 terminal 7 Vss for the 485 output.
CE-AJ12-**BS3 wiring diagram
(Terminal 7 output is +5 V to provide 5V output (<20mA), figure 6.2 terminal 7 Vss for the 485 output.
CE-AJ12-**MN1 wiring drawing
Wiring diagram of S5 case
² Available with wide power supply: DC: 10-30V or 10-55V
² With odd parity, even parity, no parity, 2 stop bits and other communication methods are free to set.
² Communication speed optional, the maximum communication speed to 115200 bps.
² The intelligent transducer with the smallest size and wide current measurement range in the peer
² Electroplating has a positive and negative cumulative, and power-down storage function.
² With red and green light-emitting diode instructions function, the red light indicates the normal operation of the product (100mS flashing), the green light indicates the product communication.
² High anti-interference ability, the input, output and power port to resist the surge voltage up to 2KV or more.